fieldcommunicator

Pepperl+Fuchs NJ50-FP-N-P4 Inductive Sensors NJ50-FP-N-P4 Sw

Pepperl+Fuchs NJ50-FP-N-P4 Inductive Sensors NJ50-FP-N-P4 Switches Arrived


 

Features of Pepperl+Fuchs NJ50-FP-N-P4 Inductive Sensors NJ50-FP-N-P4 Switches Arrived

Inductive sensor NJ50-FP-N-P4
Comfort series
NAMUR sensors must be operated with approved switch amplifiers.
 
 
Datasheet excerpt: Technical data of Pepperl+Fuchs NJ50-FP-N-P4 Inductive Sensors NJ50-FP-N-P4 Switches Arrived
 
General specifications of Pepperl+Fuchs NJ50-FP-N-P4 Inductive Sensors NJ50-FP-N-P4 Switches Arrived
 
Switching function Normally closed (NC)
Output type NAMUR
Rated operating distance 50 mm
Installation non-flush
Assured operating distance 0 ... 40.5 mm
Reduction factor rAl 0.4
Reduction factor rCu 0.3
Reduction factor r304 0.85
Output type 2-wire
 
 
Nominal ratings of Pepperl+Fuchs NJ50-FP-N-P4 Inductive Sensors NJ50-FP-N-P4 Switches Arrived
 
Nominal voltage 8.2 V (Ri approx. 1 kΩ)
Switching frequency 0 ... 100 Hz
Current consumption
Measuring plate not detected min. 3 mA
Measuring plate detected ≤ 1 mA
 
 
Compliance with standards and directives of Pepperl+Fuchs NJ50-FP-N-P4 Inductive Sensors NJ50-FP-N-P4 Switches Arrived
 
Standard conformity
NAMUR EN 60947-5-6:2000
IEC 60947-5-6:1999
Standards EN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
 

 
Approvals and certificates of Pepperl+Fuchs NJ50-FP-N-P4 Inductive Sensors NJ50-FP-N-P4 Switches Arrived
 
IECEx approval
Equipment protection level Ga IECEx PTB 11.0021X
Equipment protection level Gb IECEx PTB 11.0021X
Equipment protection level Da IECEx PTB 11.0021X
ATEX approval
Equipment protection level Ga PTB 00 ATEX 2032 X
Equipment protection level Gb PTB 00 ATEX 2032 X
Equipment protection level Da PTB 00 ATEX 2032 X
FM approval
Control drawing 116-0165
UL approval
Ordinary Location E87056
Hazardous Location E501628
Control drawing 116-0451
CSA approval cCSAus Listed, General Purpose
CCC approval CCC approval / marking not required for products rated ≤36 V
 
 
Ambient conditions of Pepperl+Fuchs NJ50-FP-N-P4 Inductive Sensors NJ50-FP-N-P4 Switches Arrived
 
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
 
 
Mechanical specifications of Pepperl+Fuchs NJ50-FP-N-P4 Inductive Sensors NJ50-FP-N-P4 Switches Arrived
 
Connection type screw terminals
Information for connection A maximum of two conductors with the same core cross section may be mounted on one terminal connection!
tightening torque 1.2 Nm + 10 %
Core cross-section up to 2.5 mm2
Minimum core cross-section without wire end ferrule 0.5 mm2 , with connector sleeves 0.34 mm2
Maximum core cross-section without wire end ferrule 2.5 mm2 , with connector sleeves 1.5 mm2
Housing material PBT/metal
Sensing face PBT
Degree of protection IP67
Note Tightening torque: 1.8 Nm (housing)
 
 
Product of Pepperl+Fuchs NJ50-FP-N-P4 Inductive Sensors NJ50-FP-N-P4 Switches Arrived
 
KFA6-DU-Ex1.D Switch Amplifier, Timer Relay
1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact and transistor output, Adjustable output timer functions from 10 ms ... 60 min, Input frequency up to 80 Hz; pulse divider up to 1 kHz, Reset function, Configurable by keypad, Line fault detection (LFD)
 
KFA6-SOT2-Ex2 Switch Amplifier
2-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Passive transistor output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
 
KFA6-SR2-Ex1.W Switch Amplifier
1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511
 
KFA6-SR2-Ex1.W.LB Switch Amplifier
1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511
 
KFA6-SR2-Ex2.W Switch Amplifier
2-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511
 
KFA6-SR2-Ex2.W.IR Switch Amplifier
2-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Latching relay contact output, Line fault detection (LFD)
 
KFD2-SOT3-Ex1.LB Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Passive transistor output, non-polarized, Passive fault output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508


Pepperl+Fuchs NJ50-FP-N-P4 Inductive Sensors NJ50-FP-N-P4 Switches Arrived
 
KFD2-SOT3-Ex1.LB.IO Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Isolated passive transistor output, non-polarized, Isolated passive fault output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
 
KFD2-SOT3-Ex2 Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs, Reversible mode of operation, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508
 
KFD2-SOT3-Ex2.IO Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Isolated passive transistor output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
 
KFD2-SR2-Ex1.W Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511
 
KFD2-SR2-Ex1.W.LB Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511
 
KFD2-SR2-Ex2.W Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511


Pepperl+Fuchs NJ50-FP-N-P4 Inductive Sensors NJ50-FP-N-P4 Switches Arrived
 
KFD2-SR3-Ex2.2S Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), 2 x 2 relay contact outputs with AND logic, Reversible mode of operation, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508
 
KFD2-SRA-Ex4 Switch Amplifier
4-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 50 % less wiring, 2:1 technology, Relay contact output, Line fault detection (LFD), Reversible mode of operation
 
KFD2-ST3-Ex1.LB Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 active transistor outputs, Usable as signal splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508
 
KFD2-ST3-Ex2 Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Active transistor output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
 
KCD2-SR-Ex1.LB Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Relay contact output, Fault relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
 
KCD2-SR-Ex2 Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508

Pepperl+Fuchs NJ50-FP-N-P4 Inductive Sensors NJ50-FP-N-P4 Switches Arrived
 
KCD2-SON-Ex1 Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs (resistive acc. to EN 60947-5-6), Line fault transparency (LFT), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
 
KCD2-SOT-Ex1.LB Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs, Usable as signal splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
 
KCD2-SOT-Ex2 Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
 
KCD2-SOT-Ex2.SP Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508
 
KCD2-ST-Ex1.LB Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 active transistor outputs, Usable as signal splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
 
KCD2-ST-Ex2 Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 active transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508


Pepperl+Fuchs NJ50-FP-N-P4 Inductive Sensors NJ50-FP-N-P4 Switches Arrived
 
KFA5-SR2-Ex1.W Switch Amplifier
1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511
 
KFA5-SR2-Ex1.W.LB Switch Amplifier
1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511
 
KFA5-SR2-Ex2.W Switch Amplifier
2-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511
 
KFD2-DU-Ex1.D Switch Amplifier, Timer Relay
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact and transistor output, Adjustable output timer functions from 10 ms ... 60 min, Input frequency up to 80 Hz; pulse divider up to 1 kHz, Reset function, Configurable by keypad, Line fault detection (LFD)
 
KFA5-SOT2-Ex2 Switch Amplifier
2-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Passive transistor output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508

Pepperl+Fuchs NJ50-FP-N-P4 Inductive Sensors NJ50-FP-N-P4 Switches Arrived
 
KCD2-SON-Ex1.R1 Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs (resistive), Application-specific outputs, Line fault transparency (LFT), Usable as signal splitter (1 input and 2 outputs), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
 
KCD2-SON-Ex1.R2 Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, Application-specific outputs, Usable as signal splitter (1 input and 2 outputs), 2 passive transistor outputs (resistive), Line fault transparency (LFT), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
 
KCD2-SON-Ex1.R3 Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, Application-specific outputs, Usable as signal splitter (1 input and 2 outputs), 2 passive transistor outputs (resistive), Line fault transparency (LFT), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
 
KCD2-SON-Ex1.SP Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs (resistive acc. to EN 60947-5-6), Line fault transparency (LFT), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508
 
KCD2-SON-Ex2 Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs (resistive acc. to EN 60947-5-6), Line fault transparency (LFT), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
 
KCD2-SON-Ex2.R1 Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs (resistive), Application-specific outputs, Line fault transparency (LFT), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
 
KCD2-SON-Ex2.R2 Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Application-specific outputs, 2 passive transistor outputs (resistive), Line fault transparency (LFT), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
 
KCD2-SON-Ex2.R3 Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Application-specific outputs, 2 passive transistor outputs (resistive), Line fault transparency (LFT), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
 
KCD2-SON-Ex2.SP Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs (resistive acc. to EN 60947-5-6), Line fault transparency (LFT), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508
 
KCD2-SOT-Ex1.LB.SP Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs, Usable as signal splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508
 
KCD2-ST-Ex1.LB.SP Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 active transistor outputs, Usable as signal splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508
 
KCD2-ST-Ex2.SP Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 active transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508


Pepperl+Fuchs NJ50-FP-N-P4 Inductive Sensors NJ50-FP-N-P4 Switches Arrived
 
KFA4-SR2-Ex2.W Switch Amplifier
2-channel, Control circuit EEx ia IIC, Reversible mode of operation, 1 relay contact output (change-over contact) per channel, EMC acc. to NAMUR NE 21, LB/SC monitoring, Up to SIL 2 acc. to IEC 61508/IEC 61511
 
KFA5-DU-Ex1.D Switch Amplifier, Timer Relay
1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact and transistor output, Adjustable output timer functions from 10 ms ... 60 min, Input frequency up to 80 Hz; pulse divider up to 1 kHz, Reset function, Configurable by keypad, Line fault detection (LFD)
 
KFA5-SR2-Ex2.W.IR Switch Amplifier
2-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Latching relay contact output, Line fault detection (LFD)
 
KFD2-SOT3-Ex2.IO-Y1 Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Isolated passive transistor output, TTL level, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
 
KFA4-SR2-Ex1.W Switch Amplifier
1-channel, Control circuit EEx ia IIC, Reversible mode of operation, 1 relay contact output (change-over contact), EMC acc. to NAMUR NE 21, LB/SC monitoring, Up to SIL 2 acc. to IEC 61508/IEC 61511
 
KFA4-SR2-Ex1.W.LB Switch Amplifier
1-channel, Control circuit EEx ia IIC, Reversible mode of operation, Output I: relay contact output (change-over contact), Output II: optionally signal output/fault signal, EMC acc. to NAMUR NE 21, LB/SC monitoring, Up to SIL 2 acc. to IEC 61508/IEC 61511
 
KFD2-SOT2-Ex1.LB Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Passive transistor output, non-polarized, Passive fault output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
 
KFD2-SOT2-Ex1.LB.IO Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Isolated passive transistor output, non-polarized, Isolated passive fault output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
 
KFD2-SOT2-Ex2 Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Passive transistor output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
 
KFD2-SOT2-Ex2.IO Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Isolated passive transistor output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
 
KFD2-SR2-Ex2.2S Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), 2 x 2 relay contact outputs with AND logic, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
 
KFD2-ST2-Ex1.LB Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Active transistor output, Active fault output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
 
KFD2-ST2-Ex2 Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Active transistor output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
 
KFD2-SOT2-Ex2.IO-Y181008 Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Isolated passive transistor output, TTL level, Line fault detection (LFD), Reversible mode of operation
 
Pepperl+Fuchs NJ50-FP-N-P4 Inductive Sensors NJ50-FP-N-P4 Switches Arrived
 
KCD2-SR-Ex1.LB.SP Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Relay contact output, Fault relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508

KCD2-SR-Ex2.SP Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508
 
Pepperl+Fuchs NJ50-FP-N-P4 Inductive Sensors NJ50-FP-N-P4 Switches Arrived
 
NCN4-12GM60-B3-C2-V1
NCN3-F25F-N4-V1
NJ4-12GM-N-V1
NJ4-12GK-SN
R2-SP-IC8
HID2026
KFD2-STC4-EX1
NJ50-FP-N-P4

Pepperl+Fuchs NJ50-FP-N-P4 Inductive Sensors NJ50-FP-N-P4 Switches Arrived
 
NBB0.8-4M25-E0
NBB0.8-4M25-E1
NBB0.8-4M25-E2
NBB0.8-4M25-E3
NBB0.8-5GM25-E0
NBB0.8-5GM25-E1
NBB0.8-5GM25-E2
NBB0.8-5GM25-E3
NBB1-4GM22-E2
 
NBB1,5-5GM25-E3-V3
NBB1,5-8GM40-E0-V1
NBB1,5-8GM40-E0-V3
NBB1,5-8GM40-E2-V1
NBB1,5-8GM40-E2-V3
NBB1,5-8GM40-Z0
NBB1,5-8GM40-Z1
NBB1,5-8GM50-A0-V1
NBB1,5-8GM50-A2-V1
NBB1,5-8GM50-Z3-V3
NBB1,5-8GM60-A0
NBB1,5-8GM60-A2
NBB1.5-5GM25-E2-V3
 
Pepperl+Fuchs NJ50-FP-N-P4 Inductive Sensors NJ50-FP-N-P4 Switches Arrived
 
NBB2-6,5M25-E1-V3
NBB2-6,5M25-E2-V3
NBB2-6,5M25-E3-V3
NBB2-6,5M30-E2
NBB2-8GM25-E1-V3
NBB2-8GM25-E2-V3
NBB2-8GM25-E3-V3
NBB2-8GM30-A0-V1
NBB2-8GM30-A2-V1
NBB2-8GM30-E0
NBB2-8GM30-E0-V1
NBB2-8GM30-E2
NBB2-8GM30-E2-V1
NBB2-8GM40-E0-V1
NBB2-8GM40-E2-V1
NBB2-8GM40-E2-V1-3G-3D
NBB2-8GM40-E2-V3
NBB2-8GM50-E0
NBB2-8GM50-E2
NBB2-12GK50-E0
NBB2-12GK50-E2
NBB2-12GM40-E0
NBB2-12GM40-E0-V1
NBB2-12GM40-E1
NBB2-12GM40-E2
NBB2-12GM40-E2-V1
NBB2-12GM40-E3
NBB2-12GM40-Z0
NBB2-12GM40-Z0-3G-3D
NBB2-12GM40-Z0-V1
NBB2-12GM40-Z3-V1
NBB2-12GM50-E0
NBB2-12GM50-E0-V1
NBB2-12GM50-E2
NBB2-12GM50-E2-V1
NBB2-12GM60-A0
NBB2-12GM60-A0-V1
NBB2-12GM60-A2
NBB2-12GM60-A2-V1

Pepperl+Fuchs NJ50-FP-N-P4 Inductive Sensors NJ50-FP-N-P4 Switches Arrived
 
NBB4-12GM30-E2
NBB4-12GM30-E2-V1
NBB4-12GM30-E2-V3
NBB4-12GM30-E3
NBB4-12GM30-E3-V1
NBB4-12GM50-A0
NBB4-12GM50-A0-V1
NBB4-12GM50-A2
NBB4-12GM50-A2-V1
NBB4-12GM50-E0
NBB4-12GM50-E0-V1
NBB4-12GM50-E2
NBB4-12GM50-E2-3G-3D
NBB4-12GM50-E2-V1
NBB4-12GM50-E2-V1-3G-3D

Pepperl+Fuchs NJ50-FP-N-P4 Inductive Sensors NJ50-FP-N-P4 Switches Arrived
 
NBB5-18GK50-E0
NBB5-18GK50-E2
NBB5-18GK-WO
NBB5-18GK-WS
NBB5-18GM20-E2
NBB5-18GM20-E2-V1
NBB5-18GM40-E2
NBB5-18GM40-Z0
NBB5-18GM40-Z0-V1
NBB5-18GM40-Z3-V1
NBB5-18GM50-E0
NBB5-18GM50-E0-V1
NBB5-18GM50-E2
NBB5-18GM50-E2-V1
NBB5-18GM60-A0
NBB5-18GM60-A0-V1
NBB5-18GM60-A2
NBB5-18GM60-A2-V1
NBB5-18GM60-A2-V1-3G-3D
NBB5-18GM60-WO
NBB5-18GM60-WS

Pepperl+Fuchs NJ50-FP-N-P4 Inductive Sensors NJ50-FP-N-P4 Switches Arrived
 
NBN8-18GM40-Z0
NBB8-18GM30-E2
NBB8-18GM30-E2-V1
NBB8-18GM30-E3
NBB8-18GM30-E3-V1
NBB8-18GM50-E0
NBB8-18GM50-E0-V1
NBB8-18GM50-E0-V1-M
NBB8-18GM50-E1-M
NBB8-18GM50-E1-V1-M
 
Pepperl+Fuchs NJ50-FP-N-P4 Inductive Sensors NJ50-FP-N-P4 Switches Arrived
 
NBB3-V3-Z4-V NBB2-6,5M25-E3-V NBB2-6,5M25-E2-V NBB0.8-4M25-E NCB50-FP-A2-P1-3G-3 NBN40-L2M-A0-V NBB10-30GM-50-E2-C3-V NBB0.6-4GM22-E SJ3.5-N-Y04611 NCB15+U1+N NBN15-30GM40-Z NBB2-8GM30-A0-V NBB2-6,5M30-E NBB2-8GM25-E1-V NBB2-8GM25-E2-V NBN8-18GM40-Z NBN8-18GM40-Z NBB2-8GM25-E3-V NBB2-8GM25-E3-V NBB2-8GM25-E2-V NBB0.8-4M25-E NBB5-18GM50-E2-V NBB0.8-4M25-E NBB0.8-4M25-E NBB0.8-5GM25-E NBB0.8-4M25-E NBB0.8-5GM25-E NJ50-FP-N-P NBN40-U1-A NBB20-U1-E0- NBB2-V3-E1-V NBB2-6,5M25-E2-V NBB2-6,5M25-E1-V NBB1.5-5GM25-E2-V NBB1,5-8GM60-A NBB1,5-8GM60-A NBB1,5-8GM50-Z3-V NBB1,5-8GM50-A2-V  NBB1,5-8GM50-A0-V NBB1,5-8GM40-Z NBB1,5-8GM40-Z NBB1,5-8GM40-E2-V NBB5-18GM60-AO-V NBB5-18GM60-A NBB1,5-8GM40-E2-V
 
 
Pepperl+Fuchs NJ50-FP-N-P4 Inductive Sensors NJ50-FP-N-P4 Switches Arrived
 
KFD2-CD-EX1.32
KFD2-STC4-EX1
KFD2-UT2-EX1
KFD2-SR2-Ex1.W
KFD2-SCD-EX1.LK
KFD2-SOT2-EX2
KFD2-STC4-EX2
KFD2-SR2-Ex2.W
KFD2-STC4-EX1.2O
KFD0-SCS-EX1.55
KFD2-WAC2-EX1.D
KFD0-RSH-1
KFD0-HMS-16
KFU8-UFC-EX1.D
KFD2-SOT2-EX2
KFD2-STC4-EX1
KFD2-UT2-EX2
KFD2-VR4-EX1.26
KFD2-EB2.R4A.B
KFD2-BR-1.PA.93
KFD2-CRG2-EX1.D
KFU8-DWB-1.D
KFU8-DW-1.D
KFU8-UFT-EX2.D
KFA6-DWB-1.D
Z787.H
UPR-03
HID2072
KFD2-SCD-EX1.LK
KFD2-CD-EX1.32
KFD2-UT2-Ex1
KFD2-STC4-EX2
KFD2-SR2-EX2.W
KFA6-STR-1.24.500
KFD2-CRG-1.D
KFD2-BR-EX1.3PA.93
KFD2-DWB-EX1.D
KFD2-SCD-EX1.LK
KFD2-SR2-EX1.W.LB
KFD2-SR2-EX2.W
KFD2-STC4-1.20
KFD2-STC4-EX1
KFD2-STC4-EX1.20
KFD2-UT2-2
KFD2-UT2-EX1
KFD2-SOT2-EX2
KFD2-SOT2-EX1.LB
KFD2-STC3-EX1
KFD2-SR2-EX1.W.LB
KFD2-GUT-1.D
KFD0-RSH-1
K-CJC-GN
LVL-T1-G3S-E5PG-NA
ML4-T-KSU/33
ML5-8-400/30/115
ML5-8-400/32/115
MLV11-54-G/47/112
MLV40-8-H-1463

Pepperl+Fuchs NJ50-FP-N-P4 Inductive Sensors NJ50-FP-N-P4 Switches Arrived
 
NBB15-30GM50-WO
NBB2-12GM50-E0
NBB2-12GM50-E2
NBB5-18GM50-E2
NBB5-18GM50-E0
NBN4-12GM50-E0
NBN4-12GM50-E2
NBN8-18GM40-Z0
NBN8-18GM50-E0
NBN8-18GM50-E2
NCN50-FP-W-P1
OBE10M-18GM60-SE4
OBE10M-18GM60-SE5
PVM58N-011AGR0BN-1213
10-11636-R-1024
10-11636_R-1024
RLK39-54-Z/31/40A/116
RVI50N-09BK0A3TN-01000
RVI50N-09BK0A3TN-01024
NBB5-18GM50-E2-V1
NBN15-30GM50-E0
NBB15-30GM50-WS
NBB2-V3-E2
NBN15-30GM50-E2
NBN15-30GM60-A2-V1
OBT200-18GM60-E4
OBT200-18GM60-E5
RVI58N-011K1R61N-01024
RVI78N-10CK2A31N-01000
NJ4-30GM-N-200

Pepperl+Fuchs NJ50-FP-N-P4 Inductive Sensors NJ50-FP-N-P4 Switches Arrived
 
NBB1.5-8GM50-E2
NBB2-12GM50-E2
NBB2-12GM50-E0
NBN4-12GM50-E2
NBN4-12GM50-E0
NBB4-12GM50-E2
NBB4-12GM50-E0
NBB5-18GM50-E2
NBB5-18GM50-E0
NBB5-18GM50-A2
NBB5-18GM40-Z0
NBN8-18GM50-E2
NBN8-18GM50-E0
NBB8-18GM50-E2
NBB8-18GM50-E0
NBN8-18GM40-Z0
NBB10-30GM50-E2
NBB10-30GM50-E0
NBN15-30GM50-E2
NBN15-30GM40-Z0
NJ1.5-8GM40-E2-V1
NBB1.5-8GM40-E2-V1
NJ2-12GM40-E2-V1
NBB4-12GM50-E2-V1
NBB5-18GM50-E2-V1
NBN12-18GM50-E2-V1
NEB12-18GM50-E2-V1
NBB10-30GM50-E2-V1
NBB15-30GM50-E2-V1
NBB20-L2-E2-V1

Pepperl+Fuchs NJ50-FP-N-P4 Inductive Sensors NJ50-FP-N-P4 Switches Arrived
 
NCN15-30GM40-NO-V1
NJ15+U1+E2
NJ15+U1+A2
NJ20+U1+E2
NJ30+U1+E2
NJ40+U1+E2
NBB15-U1-E2
NBB15-U1-A2
NBB20-U1-E2
NBN30-U1-E2
NBN40-U1-E2
NCN25-F35-A2-250-V1
CJ4-12GM-E
NJ15-30GM-N
SJ3.5-N
NBN8-18GM60-WS
NBB15-30GM50-WS
NBB15-30GM50-WO
GLV18-8-450/115/120
NJ15+U1+W
NJ20+U1+W
NJ30+U1+W
NJ40+U1+W
RLK39-54-Z/31/40A/116
LA39/LK39-Z/31/40A/116
SJ30-A2
SJ30-WS
NBN40-U1-E2
NBN30-U1-E0
NBN8-18GM60-WO
NRN75-FP-A2-P3-V1
RL39-8-2000/32/40A/82A/116
UC2000-30GM-IUR2-V15
NJ5-18GK-N-150
NCN25-F35-A2-250-V1
NCN15-30GM40-ZO
NBB10-30GM50-WO
NEB12-18GM50-E2
NBN25-30GM50-E2
UDC-18GM-400-3E3
UC500-30GM-IUR2-V15

Pepperl+Fuchs NJ50-FP-N-P4 Inductive Sensors NJ50-FP-N-P4 Switches Arrived
 
IA40-FP-I3-P1
MLV40-8-500/47/92
UB6000-30GM-E5-V15
NBN15-30GM60-A2
VAA-4E4A-G4-ZE/E2
IA8-M1K-13
CJ10-30GM-WS
NJ2-12GM40-E2-V1
NJ1.5-6.5-N
NJ5-18GM50-A2-V1
NBN12-18GM50-E2-V1
MB60-12GM50-E2-V1
CJ10-30GM-E2
RLK31-8-2500-IR/31/115
NBN40-U1-A2
NCN40+U1+NO
MC60-12GM50-1N
UB2000-F42-U-V15
NJ1.5-8GM40-E2
L32/LV32/47/73C
RL32-54/47/73C
OBS4000-18GM60-E4
NJ15-M1-E2-V1
NCN8-18GM40-NO-V1
CJ8-18GM-E2
NCB1.5-8GM25-N0
NBB8-18GM60-A2
NJ10-30GM50-E2
UB4000-F42-U-V15
NJ5-18GM50-A2-V1
NJ15+U1+DW1-1
GLV12-8-200/36/40B/115
NBB20-L2-E2-V1-3G-3D
VBG-PB-K20-DMD
NEN40-30GM60-E2-V1
NJ2-11-N-G
NBN3-F69-E2-V1
UC500-D1-3K-V7
IA8-30GM-I3
NJ15+U4+W-T
ML4.1-8-H-20-RT/95/110
ML4.1-8-H-60-RT/95/110
NBN15-30GK50-E2
IA40-FP-13-P1
UC300-30GM-IUR2-V15
NJ50-FP-E-P1
NCN4-12GM35-NO
NBB5-18GM60-AO-V1
NBB1.5-8GM50-A2-V1
NBN4-F29-E2
NJ6-F-A2
NCB4-12GM60-B3-V1
IA5-18GM60-I3-V1
NBN3-F25-E8-V1
RC10-14-N0
GLV12-6/37/40B/115
RLK28-55/31/116
9402 8*8
9404 12*12
NJ4-12GK-N

Pepperl+Fuchs NJ50-FP-N-P4 Inductive Sensors NJ50-FP-N-P4 Switches Arrived
 
UC2000-30GM-E6R2-V15
NCB2-12GM35-NO-V1
NCB2-12GM35-NO
V1-W-N-10M-PUR
NCN50-FP-N0-P1
NCB40-FP-A2-P1
CJ10-30GK-E2
UDC-18GM-400-3E1
UBE1500-F64-SE2-V3
ML7-8-H-140-RT/59/6/115/136
OBT500-18GM60-E4
OBS4000-18GM60-E4
RLK31-6/31/115
LVL-T1-G3S-E5PG-WH
M12-F1/76b/115
M13/MV13/32/40b/73c
ML4-8-H-M-1348
ML4-8-KSU/43/70A
ML4-8-KSU-1205
ML4-8-KSU-2324
ML4-8-KSU-2325
ML4-T-KSU/33
ML5-T-GA-1385/33
ML5-T-KSU/15
ML18-2397
ML4.1-8-H-40-RT/95/110
ML5-8-400/30/115
ML5-T-GA-1385/33
ML5-T-KSU/15
ML7-8-H-350-IR/65a/115b/120
ML8-6/25/103/143
MLV11-54-G/47/112
MLV11-8-H-150/47/65a/76a/112
MLV40-LL-IR/47/92
MLV40-LL-IR-1347
MV11/47/112
MV12-F1/82b/115/128
MV12-F1/82b/115/128

Pepperl+Fuchs NJ50-FP-N-P4 Inductive Sensors NJ50-FP-N-P4 Switches Arrived
 
NBB0,8-5GM25-E0
NBB1,5-8GM50-E2
NBB1,5-8GM60-A0
NBB10-30GM40-Z0
NBB10-30GM50-WO
NBB15-30GM50-WO
NBB15-U1K-E2-3G-3D
NBB15-U1K-E2-3G-3D
NBB20-L2-A2-C-V1
NBB20-L2-B3B-V1
NBB20-L2-E0-V1
NBB2-V3-E2
NBB5-18GM40-Z0
NBB5-18GM50-E2-V1
NBB5-F9-E2
NBB6-F-B3
NBB8-18GM60-B3-V1
NBN15-30GM40-Z0
NBN15-30GM50-E2-V1
NBN2-8GM40-E2-V3
NBN30-U1-A2
NBN3-F25-E8-V1
NBN3-F25-Z8-V1
NBN3-F31-E8-V1
NBN3-F31-E8-V1-3G-3D
NBN40-L2-Z4-V1
NBN4-12GM50-E2
NBN4-12GM50-E2-V1
NBN4-V3-E2
NBN5-F7-E2
NBN8-18GK50-E0
NCB15+U1+U
NCB15+U1+Z2
NCB15-30GM50-Z4
NCB40-FP-W-P1
NCB4-12GM40-Z4-V1
NCB4-12GM60-B3B-V1
NCB4-12GM60-B3-V1
NCB50-FP-A2-P1
NCB50-FP-E2-P1
NCN20+U1+Z2
NCN25-F35-A2-250-V1
NBB8-18GM50-E0-V1
NCN30+U1+Z2
NCN3-F25F-N4-V1
NCN3-F31K-N4
NCN40+U1+E2
NCN40+U1+Z2
NCN50-FP-A2-P1

Pepperl+Fuchs NJ50-FP-N-P4 Inductive Sensors NJ50-FP-N-P4 Switches Arrived
 
NJ0.2-10GM-N-Y199308
NJ1,5-18GM-N-D
NJ1,5-8GM-N
NJ1,5-8-N-Y18812
NJ10-30GK-E2-T
NJ15+U4+W-T
NJ2,5-14GM-N-V1-Y2114
NJ20+U10+E2
NJ20S+U1+N
NJ2-11-SN-G
NJ2-12GM40-E2-3D
NJ2-6,5-40-E2
NJ2-8GM40-E0
NJ2-8GM40-E2
NJ2-D-US-2.062-V12
NJ2-PD-US-2.062-V93
NJ2-V3-N
NJ4-12GM-N-V1
NJ4-30GM-N-200
NJ50-FP-E-P1
NJ5-18GK-N-150
NJ5-18GK-N-150-15M
NJ5-18GM50-E2-5M
NJ5-18GM-N-5M
NJ6-F-E2-5M
NJ8-18GK-N-150
NMB5-18GM80-US-FE
NMB5-18GM85-US-FE-V12
NMB8-30GM85-US-FE-V12
NRN35-L3-A2-C-V1
UB2000-30GM-E4-V15
UB300-18GM40-E4-V1
UB500-18GM75-E5-V15
UBE500-18GK-SE2-V1
UC2000-30GM-IUR2-V15
UDC-18GM-400-3E1

Pepperl+Fuchs NJ50-FP-N-P4 Inductive Sensors NJ50-FP-N-P4 Switches Arrived
 
VAA-2E2A-G2-S/EA2
VAA-2E2A-G2-S/EA2
VAA-4E4A-G2-ZA/EA2
VAA-4E4A-G4-ZE/E2
VAA-4E4A-KE-ZE/E2
VAA-4E4A-KE-ZE/R
VAA-4E-G2-ZA
VAA-4E-G4-ZE
VAA-4E-KE-ZE
VAN-115/230AC-K21-EFD
VAS-2A-K12-U
VAZ-DK-G1
VAZ-FK-S-YE
VB12-220-S-R
VBA-4E3A-KE-ZE/E2?
VBA-4E-G2-ZA
VBA-4E-G4-ZE
VDM18-100/32/105/122
VL18-54-M/40a/118/128
KS11/KSE11/59/103/115
KS-LL-IR-1320
KSU-LL-IR-1320
LD28-F1/76a/105
LD28-F1-3057/35/76a/115b
LD39/LV39/30/40a/116/126a
LFL2-CK-U-PVC3
LV28-F1/47/82b/105
LV28-F1-3057/35/47/115b
GD18/GV18/115/120
IA40-FP-I3-P1
IA5-18GM-I3
IA8-30GM-I3
IA8-M1K-I3
DAD15-8P-R-2388
DK10-LAS/76a/110/124
CBN12-F64-E3
CCB10-30GM80-N1
ML4-8-KSU/43/70A
CJ40-FP-A0-P1
UC2000-F43-2KIR2-V17
ML7-8-H-140-RT/59/6/115/136
NCB50-FP-E2-P4
ML5-6-RT/32/115
NCB1.5-18GM60-E2-D
NJ15+U1+DW1-10
KT11-50/25/98A/102
NBN30-L2-E2-V1
BVM58N-032AVR0NN-0610
BVS58N-011AVR0NN-0013
10-11636-A-2500
10-11636-R-2500
14-14366-1024
14-14361-1024
14-14366-4096

Pepperl+Fuchs NJ50-FP-N-P4 Inductive Sensors NJ50-FP-N-P4 Switches Arrived
 
30-360X_A-1000
30-3601IA-0500
30-36M1_R-60
10-01636_R-1024
10-11631-R-1024
DVM58N-011AGR0BN-1213
FVM58N-011K2A3BN-1213
FVM58N-011K2R3GN-1213
FVS58N-011ADR3BN-0013
FVS58N-011K2R3GN-0013
FVS58N-011K2R3BN-0013
FVM58I-011K2A3BN-1213
FVM58N-011K2R3GN-1213
PVM58N-011AGR0BN-1213
PVM58N-032AGROBN-1213
PVS58N-022AGROBN-0013
AVM58N-011K1R0GN-1213
PSS58N-F2AAGR0BN-0013
RVI58N-011K1R61N-00500
RVI50N-09BK0A3TN-01000
RVI58N-011K1R61N-00500
RVI58N-011K1R61N-01000
TVI40N-14TK0T6TN-01000
RVI58N-032K1R66N-01000
RVI58N-011AAA61N-00500
RVI58N-011K1A61N-00100
RVI50N-09BK0A3TN-01500
RHI90N-0HAK1R61N-01024
RHI90N-0FAK1R61N-02048
RHI90N-0NAK1R66N-01000
RVI58N-011K1R61N-00100
RHI58N-0BAK1R66N-01024
RHI58N-0BAK1R61N-01000
RVI58X-011K1R61N-01024
RVI58N-011K1A61N-05000
RHI58N-0BAK1R61N-01000
RHI90N-0HAAAR61N-01024
RVI58N-012K1R61N-00500
RVI50N-09BK0A3TN-00500
RHI58N-0BAK1R61N-01000
RVI58N-011K1A61N-02048
RHI58N-0BAK1R66N-01000
RHI90N-0HAK1R6XN-01024
RHI58N-0AAK1R6XN-01000
RHI90N-0IAK1R61N-01024
RVI58N-012K1R61N-00500

Pepperl+Fuchs NJ50-FP-N-P4 Inductive Sensors NJ50-FP-N-P4 Switches Arrived

NCN4-12GM60-B3-C2-V1
NCN3-F25F-N4-V1
NJ4-12GM-N-V1
NJ4-12GK-SN
R2-SP-IC8
HID2026
KFD2-STC4-EX1
KFD2-STC5-EX1.2O
NBB20-U1-Z2
KFD0-CS-EX2.51P
KFD0-R0-EX2
KFD2-STC5-EX1
NCB2-V3-N0
NJ8-18GK-N, PN: 106464
UC4000-30GM-IUR2-V15
KFD2-UT2-EX2
KFD2-STC4-Ex1
KFD2-SR2-Ex2.W
KFD2-WAC2-EX1.D
KFD2-UFC-1.D
KFU8-UFC-EX1D
KFD2-ST2-Ex2
KFD2-SR2-EX2.2S
KFD2-STC4-EX1
KFD2-SCD-EX1.LK
KFD2-SRA-EX4
KFD2-CD2-EX2
F2-SP-IC10.1.02.02.01
KFD0-SD2-Ex1.1045
KFD2-SL2-Ex2
KFD2-SCD2-Ex2..LK
KFD2-STC4-EX2
KCD0-SD-Ex1.1245
KFU8-VCR-1
HID2032
HID2026
OJ500-M1K-E23
NBN40-U1K-N0
KCD0-SD-EX1.1245
HID2022
VDM28-15-L-IO/73C/110/122
KCD2-SD-EX1.1245
KCD2-STC-EX1.ES
KCD2-SR-EX2
F2D0-TI-EX8.FF.CGS.ST
NBB5-18GM50-E2-V1
NBB4-12GM50-E2-V1
KCD2-STC5-EX1
KCD2-STC-EX1
KFD2-DWB-Ex1.D
KCD2-STC4-EX1
Z960
KFD2-GUT-Ex1.D
KFD2-UFC-EX1.D
KFD2-CRG2-EX1.D
KFD2-SCD-EX1.LK
KFD2-STC4-EX1
KFD2-DWB-1.D.
KFD2-SR2-EX1.WLB
KFD2-SR2-EX2.W
KFD2-SR2-EX1.W
KFD2-SL2-Ex1.B
KFD2-CRG2-EX1.D
KCD2-SR-EX2
KCD0-SD-EX1.1245
FXLS2** SS316
KFD2-SR2-Ex1.W.LB
KFD2-SL2-EX1
NBN8-12GM50-E2
KFD2-STC4-Ex1
NCB8-18GM40-N0
KCD2-SR-EX1.LB
KFD0-SD2-EX1.1045
KFA5-SR2-EX2.W
HIC2031
HID2062

Pepperl+Fuchs NJ50-FP-N-P4 Inductive Sensors NJ50-FP-N-P4 Switches Arrived
 
UC2000-30GM-IUR2-V15
NJ5-18GM-N-V1
NJ5-18GM-N
KFD2-SR2-EX1.W.LB
KFD2-HLC-EX1.D.4S
KCD2-SCD-1
KCD2-RR-EX1
KFD2-VR4-EX1.26
KCD2-SR-EX1.LB
KCD2-SCD-EX1
KCD2-STC-EX1
KFD2-STC-1.2O
NJ20P-U1-A2
KCD2-STC-EX1
KFD2-STC4-1.2O
UB2000-30GM-E5-V15
KFD2-SCD2-EX2.LK
KFD2-EB2
KFD2-SCD2-EX1.LK
NJ8-18GM-N
KFA6-SR2-EX2.W
KFD2-UFC-1.D
KFU8-UFC-Ex1.D
KFA6-SR2-EX2.W
NBB15-U1-A2-T
KFD0-SD2-Ex2.1245
KCD2-SOT-Ex1.LB
KFD2-CRG2-1.D
KFD2-CRG2-EX1.D
KFD2-SR2-Ex2.W
KFD2-STC4-EX2
KFD2-UT2-EX2
KFD2-UT2-EX1
KFD2-HMM-16
KFD0-HMS-16
NJ2-V3-N-V5
NCB8-18GM40-N0
KFD2-CRG2-EX1.D
KFD2-CRG2-1.D
NBN8-18GM60-A2-V1
NJ5-18GM-N
KFD2-STC4-Ex1
KCD0-SD-EX1.1245
KFD0-CS-Ex2.50P
KFD2-CD2-EX1
KFD2-STC4-EX1
KFD2-SR2-Ex1.W.LB
UPR-03
KCD2-STC-1.2O
KFD2-STC4-1.20
KFD0-RSH-1
KCD2-SCD-Ex1
KFD2-STC4-Ex1
KFD2-SR2-Ex1.W
KFD2-STC4-Ex1.2O
KFD0-SD2-Ex1.1045
KFD2-SH-Ex1.T
UPR-E
UPR-03 (2M)
NJ50-FP-N-P1
NCB4-12GM40-N0
NCB15-30GM40-N0
KFD2-SR2-Ex2.W
ML100-55/95/103
NCN8-18GM40-Z1
KFD2-WAC2-EX1.D
NCB1,5-18GM60-E2-D-V1
NJ20+U1+N
NBN30-U1-A2
NBB15-30GM50-E2
KFD2-UT2-EX1
KFA5-SR2-EX2.W
KCD2-SR-EX2
KFD2-STC4-EX2
KFD2-STC4-EX1.2O
KFD2-STC4-2
KFD2-STC4-1.2O
KFD2-SR2-EX2.W
KFD2-SCD2-2.LK
KFD2-CD2-EX2
KFD0-RSH-1
KFD2-RSH-1.2E.L3
HID2030
KFU8-UFC-Ex1.D
KCD2-SCD-1
KFU8-UFC-Ex1.D
NJ15+U1+N
KFD2-SR2-EX2.W
KFD2-UT2-EX2
KFD2-UFC-1.D
KFD0-TR-1
KFD2-PT2-EX1-5
KFD2-CRG2-1.D
KFD2-CRG2-EX1.D
KCD2-STC-EX1
HD2-FBPS-1.25.360
KFD2-STC4-EX1.2O
NJ20+U1+N
RHI90N-0HAK1R61N-01024
NCN8-18GM40-N0
NJ1.5-18GM-N-D-V1
KCD2-STC-EX1
KFD2-SOT2-EX1.LB.IO
KCD2-SR-EX2
P-LB-2.A.1346
P-LB-2.B.1245
K-LB-2.30
KFD2-SCD-EX1.LK
KFD2-SH-EX1.T.OP
KFD2-EB2.R4A.B
KCD2-STC-Ex1.ES
KCD2-STC-EX1
KCD2-SCD-EX1
KFD2-CD-EX1.32
KFD2-SR2-EX2.W
KFD2-CD2-EX2
KFD2-STC4-EX2
KFD2-SR2-EX1.W.LB
KFD2-STC4-EX1.2O
MH04-2681F
KFA5-SR2-EX2.W
KFD2-STC4-EX2
KCD2-SR-EX2
NBN8-18GM40-Z0-V1
NBN30-U1-Z2
NBN8-18GM40-Z0
KFD2-SR2-EX1.W.LB
NBN15-30GM50-E0
NBB20-U1-E2
NBN8-12GM50-E2
NBN8-18GM50-E2
KFA5-SR2-EX2.W
NBN30-U1-Z2
NBN40-U1-E2
NBN8-18GM60-WS-V12
NJ20+U1+N
NJ8-18GM-N
NJ5-18GM-N
NBB15-30GM50-E2
KCD0-SD-EX1.1245
V1-G-2M-PVC
UB300-18GM40-E5-V1
NBB20-U1-UU
DVM58N-011AGR0BN-1213
KFD2-CRG2-EX1.D
KFD2- STC4-EX1
UC6000-30GM-IUR2-V15
UC2000-30GM-IUR2-V15
UC6000-30GM-E6R2-V15
UC4000-30GM-E6R2-V15
KCD2-STC-Ex1.ES
KFD2-CRG2-EX1.D
KFD0-SD2-EX1.10100
KFD2-UT2-EX2
KFD2-UT2-2
KFA5-SR2-EX2.W
KFD2-SR2-Ex2.W
NBB20-U1-UU
NCB10-30GM40-N0
KFD2-SR2-Ex2.W
KFD2-EB2
KFD2-SCD-EX1.LK
KFD2-SR2-Ex1.W.LB
KFD2-SRA-EX4
KFD2-SR2-EX2.2S
KCD2-STC-EX1
KFD2-CRG2-EX1.D
KFD2-UT2-EX1
KCD0-SD-EX1.1245
KFD2-UT2-EX2
KCD2-SR-EX2
KFA5-SR2-EX2.W
 
Pepperl+Fuchs NJ50-FP-N-P4 Inductive Sensors NJ50-FP-N-P4 Switches Arrived


We are specialized in intelligent instruments, including : control system, transmitters, flow meters,sensors, recorders, analyzers, control valves, controllers, PLC's, etc.
 
We mainly supply Yokogawa, Emerson, Rosemount, Fisher, Honeywell, Siemens, ABB, FLUKE, Endress+Hauser, Schneider Electric, Pepperl+Fuchs, MTL, Rockwell(Allen Bradley), Hirschmann, Eaton, Moeller, FUJI, Omron, Yaskawa, Norgren, CHINT, Hach, Weidmuller, Phoenix, SMC, Testo, ASCO, Parker, Mitsubishi, Festo, GE, CISCO, Auma, IFM, GM, Turck, Bently Nevada, MOXA, Krohne, Foxboro,Swagelok and so on.
 
Why do you choose us?
 
1. 100% original brand product, 100% quality assurance.
    If you find a fake product. Please contact us without hesitation! We afford the shipment cost! We send  you a new product asking zero cent.
 
2. Varied payment methods.
    We adopt L/C, D/A, D/P, T/T, and other methods. If you can not trust us , you can choose to pay it via Aliexpress! 100% make your money safe!
 
Packaging: Imported with original packaging or standard export packing.Customize design is acceptable.
 
Shipping: By Express(EMS,DHL,UPS,TNT, FEDEX, ARAMEX), By Air, By Sea.
 
Contact:
 
HONGKONG XIEYUAN TECH CO., LIMITED
Email:becky@hkxytech.com   Web:www.hkxytech.com
Mobile:+86-15972186287(Whatsapp & Wechat)

Previous:Pepperl+Fuchs KFD2-UT2-EX2 Universal Temperature Converter K Next:Pepperl+Fuchs KCD2-STC-1.2O SMART Transmitter Power Supply K
 Footer begin -->